33
5. API for Acquiring/Changing Parameters of VN-E4 _
5.5. Alarm Environment Setting
Setting POP Server Port Number for VN-E4
Format /api/param?application.pop.port=data
Example /api/param?application.pop.port=110
Example of Response application.pop.port&200 OK
Interpretation Change the port number setting of the POP server.
Allowed users admin, operator
Acquiring POP Server User Name Setting from VN-E4
Format /api/param?application.pop.user
Example of Response application.pop.user=somename&200 OK
Response example
when setting field is
left blank
application.pop.user=&200 OK
Interpretation Acquire the user name setting of the POP server.
Allowed users admin, operator, user
Setting POP Server User Name for VN-E4
Format /api/param?application.pop.user=data
Example /api/param?application.pop.user=somename
Example of Response application.pop.user&200 OK
Interpretation Change the user name setting of the POP server. The maximum user name size is 60 bytes. Set as follows when
this is to be left blank.
/api/param?application.pop.user=%00
Allowed users admin, operator
Setting POP Server Password for VN-E4
Format /api/param?application.pop.password=data
Example /api/param?application.pop.password=someword
Example of Response application.pop.password&200 OK
Interpretation Change the password setting of the POP server. The maximum password size is 60 bytes. Set as follows when
this is to be left blank.
/api/param?application.pop.password=%00
Allowed users admin, operator
(Note: There is no API for reading passwords.)